Err 26 — Victron
Terminal overheated
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The power terminals have overheated; the error auto-resets after cooling. Usually a wiring issue at the terminals.
Likely causes
- Undersized or wrong-type wiring
- Loose terminal bolts
Checks
- Check wiring type and strand size against the manual
- Tighten terminal bolts (isolated) and confirm the error clears
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- power terminals
- wiring
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 26 - Terminal overheated
Power terminals overheated, check wiring, including the wiring type and type of strands, and/or fasten bolts if possible. This error will auto-reset.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.