Err 21 — Victron
Current sensor issue
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The internal current measurement is out of range. It does not auto-reset; if it persists after a full power-cycle the unit likely has a hardware defect.
Likely causes
- Hardware defect in the current sensing circuit
- Bypassed PV-/Battery- minus path
Checks
- Disconnect all wiring and reconnect to restart
- Confirm the PV-/Battery- minus is not bypassing the controller
- Contact the dealer if it persists
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- current sensor
- charge controller
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 21 - Current sensor issue
The current measurement is out of range.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.