Err 201 — Victron
Internal DC voltage measurement error
severity: degradedconfidence: vendorkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
An internal (high-)voltage measurement did not match criteria. On MPPT RS/Inverter RS/Multi RS, update firmware first — limits were too strict in older versions and could trigger falsely at MPPT start/stop.
Likely causes
- Firmware older than v1.08 (false triggers)
- Broken internal measurement circuit
Checks
- Update firmware to v1.08 or newer
- Restart with the power switch
- Send for repair if it persists
Safety flags
- dc_arc
- pv_dc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- measurement circuit
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 201 - Internal DC voltage error
Applies to the MPPT RS, Inverter RS and Multi RS.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.