Err 200 — Victron
Internal DC voltage error
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
An internal DC-DC converter diagnostic failed. It does not auto-reset; persistent failure indicates a faulty unit.
Likely causes
- Faulty internal DC-DC converter
Checks
- Restart the unit with the power switch
- Replace the unit if the error persists
Safety flags
- dc_arc
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- DC-DC converter
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 200 - Internal DC voltage error
The unit performs internal diagnostics when activating its internal DC-DC converter.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.