Err 20 — Victron
Maximum Bulk-time exceeded
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The charger did not reach absorption voltage within the bulk-time limit (10 hours on Skylla AC chargers), so it stopped to protect against a shorted cell. On older solar chargers, updating firmware removes the obsolete feature.
Likely causes
- Shorted or failing cell
- Battery not reaching absorption voltage within the time limit
- Outdated charger firmware (solar chargers)
Checks
- Update solar charger firmware to latest, then reset to factory defaults and reconfigure
- For AC chargers, test the battery for a shorted cell
Safety flags
- pv_dc
Parts
- battery
- firmware
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 20 - Maximum Bulk-time exceeded
Solar Chargers The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.