Err 18 — Victron
Controller over-current
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
Current on the battery terminals exceeded the controller limit. It usually auto-resets; if not, the unit can be power-cycled.
Likely causes
- Large load switched on the battery side
- Sudden irradiance change causing a temporary power spike
- Inverter AC output overloaded
Checks
- Allow the controller to cool and provide adequate ventilation
- Reduce inverter load
- If it persists, isolate all power, wait 3 minutes, then repower
Safety flags
- lithium_battery
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- charge controller
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 18 - Controller over-current
This error will auto-reset.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.