Battery low temperature
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
Charging has stopped to avoid charging lithium (LiFePO4) cells at low temperature, which damages them.
Likely causes
- Battery below its minimum charge temperature
Checks
- Confirm battery temperature and allow it to warm before charging
- Check the low-temperature cut-off setting
Safety flags
- lithium_battery
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- battery
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 14 - Battery low temperature
The charger is stopped to avoid charging LiFePO4 batteries at low temperature as this damages the cells.