Err 116 — Victron
Calibration data lost
severity: degradedconfidence: vendorkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The unit's calibration data is missing or lost. If it is the active error the unit is faulty; if only in history while the unit works normally it can be ignored.
Likely causes
- Faulty unit
- Reverting SmartSolar firmware from v1.4x to older firmware
- Factory first-boot history entry
Checks
- If active and the unit is not working, contact the dealer for replacement
- If only in history and the unit works, ignore safely
- Re-install v1.4x firmware after an attempted downgrade
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- charge controller
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 116 - Calibration data lost
If the unit does not work and error 116 pops up as the active error the unit is faulty, contact your dealer for a replacement.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.