Err 11 — Victron

Battery high ripple voltage

severity: degradedconfidence: verifiedkind: error1 citation(s)

Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Meaning

The DC battery voltage has excessive ripple, usually from loose or undersized DC cabling. Continuous high ripple shortens inverter life; the unit retries, then locks out after repeated shutdowns.

Likely causes

Checks

Safety flags

Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.

Parts

Citations

https://www.victronenergy.com/live/mppt-error-codes

type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 11 - Battery high ripple voltage

High DC ripple is usually caused by loose DC cable connections and/or too thin DC wiring.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.