Err 11 — Victron
Battery high ripple voltage
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Meaning
The DC battery voltage has excessive ripple, usually from loose or undersized DC cabling. Continuous high ripple shortens inverter life; the unit retries, then locks out after repeated shutdowns.
Likely causes
- Loose DC cable connections
- Undersized DC wiring
- High inverter load
Checks
- Check and tighten DC cable connections (system isolated)
- Confirm DC cable size matches the manual for the current
Safety flags
- dc_arc
- lithium_battery
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- DC cabling
Citations
https://www.victronenergy.com/live/mppt-error-codes
type: vendor_kb · retrieved: 2026-11-21 · locator: § Err 11 - Battery high ripple voltage
High DC ripple is usually caused by loose DC cable connections and/or too thin DC wiring.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.