3E2 — Tajima

The p24R power supply is abnormal

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: Tajima error list

Meaning

The 24-volt power supply is abnormal. The source says to check or replace the P24R AVR or capacitor and the joint-25 card

Fix steps

  1. Check/replace the P24R AVR or capacitor
  2. Check/replace joint-25 card

Citations

https://www.theembroiderywarehouse.com/errorlist.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 8

3E2 The p24R power supply is abnormal