The needle position signal status during color change does not…
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: Tajima error list
Meaning
The needle position signal status during color change does not change for 1 second or more
Fix steps
- Check the color change motor and power supply circuit *Check the potentiometer (Needle position sensor)