FX head needle position input error

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: Tajima error list

Meaning

The FX head's needle-position input data is wrong, or the needle-position signal is missing while the main shaft rotates. The source says to set the needle count correctly and check or replace the colour-change sensor

Fix steps

  1. Set the number of needles in the system software correctly
  2. Check/replace the color change sensor

Citations

https://www.theembroiderywarehouse.com/errorlist.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 6

381 *The FX head needle position input data has an error *The FX head needle position signal is not input while the main shaft is rotating