2B1 — Tajima
No response from serial device
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: Tajima error list
Meaning
The machine started an operation over the serial interface and received no response from the device within five seconds. The source says to check the serial device connection and repair or correct the design data
Fix steps
- Check connection of serial device (TFD, PC, etc.)
- Repair or correct the design data
Citations
https://www.theembroiderywarehouse.com/errorlist.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 3
2B1 No response is received for 5 seconds since the operation was started using a serial I/F ( Serial I/F device is not correctly connected)
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.