1B3 — Tajima

Stop due to end code 1

severity: stopconfidence: verifiedkind: status1 citation(s)

Scope: Tajima error list

Meaning

The machine stopped at end code 1 in the design. The source treats these stop codes as normal programmed stops and says any operation key except the manual frame-travel keys will continue

Fix steps

  1. Press any operation key (except the manual frame travel keys) to continue

Citations

https://www.theembroiderywarehouse.com/errorlist.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 9

1B3 Stop due to end code 1
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.