80 — Growatt
CAN fault
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Growatt SPF 3500/5000 ES off-grid solar inverter
Meaning
A CAN bus communication fault in a parallel system.
Likely causes
- Parallel communication cables not connected well
- Wrong program 23 settings for the parallel system
Checks
- Check the parallel communication cables are connected well
- Check program 23 settings are correct for the parallel system
- Contact a repair centre if it persists
Safety flags
- dc_bus
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- CAN cabling
Citations
https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 40
CAN fault. — Check whether the parallel communication cables are connected well. Check whether Program 23 settings are right for the parallel system. If problem still exists, contact repair center.