05 — Growatt
Output short circuited
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Growatt SPF 3500/5000 ES off-grid solar inverter
Meaning
The AC output is short-circuited; the manual directs checking that the output wiring is connected correctly and removing the abnormal load before restarting.
Likely causes
- Short circuit on the AC output
- Abnormal or faulty load
Checks
- Check the output wiring is connected correctly
- Remove the abnormal load
Safety flags
- dc_arc
- grid_tie
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- AC wiring
- load
Citations
https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 39
Output short circuited. — Check if wiring is connected well and remove abnormal load.
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: SolarDesk.