02 — Growatt
Over temperature
severity: degradedconfidence: verifiedkind: error1 citation(s)
Scope: Growatt SPF 3500/5000 ES off-grid solar inverter
Meaning
An internal component temperature exceeded about 100 °C.
Likely causes
- Blocked airflow through the unit
- High ambient temperature
- Loose thermistor plug
Checks
- Check whether airflow is blocked or ambient temperature too high
- Check whether the thermistor plug is loose
Requires a qualified installer. Isolate and escalate to a qualified installer/electrician.
Parts
- cooling
- thermistor
Citations
https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 39
Internal temperature of component is over 100℃. — Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. Check whether the thermistor plug is loose.