D26 — Barudan
Pulse Motor Circuit Overheat
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: Barudan XS/XY series
Meaning
The pulse-motor circuit for the pantograph has overheated, so the machine stopped. The source says to power off, clean the fan and its opening, and check that the fan runs before restarting
Fix steps
- Message that the machine stopped because the pulse motor drive (pantograph) circuitry has over heated
- Power off the machine to let it cool down
- Check and clean the fan and fan opening to make sure lint or other debris is not blocking them
- Afterwards, power back On, and check that the fan is working
- If fan works and still getting D26 error, call tech support
Citations
https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 7
D26 Pulse Motor Circuit Overheat
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.