D08 — Barudan

Frame Limit Error

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: Barudan XS/XY series

Meaning

The pantograph is beyond one of the soft limits set in the MC parameters. The source says to re-centre the design origin so it traces inside the limits, and to call technical support if the limits need changing

Fix steps

  1. Message that the pantograph is beyond one of the soft limits as set in the MC parameters
  2. Re-center the origin of design so it traces inside the limits without getting this error
  3. Call tech support if soft limits need to be reset or changed in MC parameters

Citations

https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 5

D08 Frame Limit Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.