D06 — Barudan

Main Motor Trip Error

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: Barudan XS/XY series

Meaning

The main motor tripped. The source advises a restart, then turning the machine off and rotating the sewing head by hand to check for a bind; D07 covers the possible bind points

Fix steps

  1. Try to restart the machine
  2. If still getting error, turn Off and try rotating sewing head by hand and check for binds (To rotate the sewing head, remove the main drive pulley cover to get to the degree wheel and turn the degree wheel)
  3. See D07 for possible binds

Citations

https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 5

D06 Main Motor Trip Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.