D04 — Barudan

Color Change Needle Sensor Error

severity: stopconfidence: verifiedkind: error1 citation(s)

Scope: Barudan XS/XY series

Meaning

The needle-select board in the colour-change assembly is not reporting exactly one active needle sensor. Rotate the assembly by hand to clear a bind, then check the board and sensor plate if the error remains

Fix steps

  1. Needle Select Board in Color Change Assembly has a sensor for each needle
  2. One sensor at a time should always be engaged and On
  3. First manually rotate the Color change assembly to see if it clears up the problem
  4. Do not force if color change is in a bind
  5. See Error D05 for possible binds
  6. If no binds and still getting this error, check the Needle select board to see if the sensor plate is bent or if any of the sensors are broken
  7. Replace the Needle select board

Citations

https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 4

D04 Color Change Needle Sensor Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.