Spectacle Frame Error

severity: stopconfidence: verifiedkind: status1 citation(s)

Scope: Barudan XS/XY series

Meaning

The Spectacle Frame parameter is on and the requested operation is one it prohibits. The source calls it a protective message: turn the feature off in MC parameters if no spectacle frame is in use

Fix steps

  1. Spectacle Frame is a special parameter in MC
  2. When Spectacle Frame is turned On, operations are prohibited to protect the frame
  3. If a spectacle frame is not being used, turn this feature Off in MC

Citations

https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf

type: manual · retrieved: 2026-11-21 · locator: p. 3

A35 Spectacle Frame Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.