A35 — Barudan
Spectacle Frame Error
severity: stopconfidence: verifiedkind: status1 citation(s)
Scope: Barudan XS/XY series
Meaning
The Spectacle Frame parameter is on and the requested operation is one it prohibits. The source calls it a protective message: turn the feature off in MC parameters if no spectacle frame is in use
Fix steps
- Spectacle Frame is a special parameter in MC
- When Spectacle Frame is turned On, operations are prohibited to protect the frame
- If a spectacle frame is not being used, turn this feature Off in MC
Citations
https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 3
A35 Spectacle Frame Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.