A08 — Barudan
Memory is Full or Design Memory Read Error
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: Barudan XS/XY series
Meaning
The control could not store or read a design because memory is full or the design file is damaged. The source says to delete designs first, then rename or replace the problem design, and reformat the internal CF card if no design will read
Fix steps
- Check to see if the memory is full first. Delete some designs if full
- This could also be a problem reading a design into memory. Try renaming the problem design, or try reading another design that’s verified good
- If no designs will read into memory, may need to reformat the internal CF memory card. Call tech support
Citations
https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 1
A08 Memory is Full or Design Memory Read Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.