A01 — Barudan
No or Low Battery Voltage Error
severity: stopconfidence: verifiedkind: error1 citation(s)
Scope: Barudan XS/XY series
Meaning
The control's backup battery is low or flat. The source says it appears after the machine has been off for a long period or after a replacement CPU board, and the machine needs to stay powered for 24 hours to recharge it
Fix steps
- If machine has been powered off for a long period time, or a replacement CPU board was installed, the battery maybe low and need recharged
- Leave machine on for 24 hours to recharge battery
- If battery doesn’t recharge, call tech support for info on replacement
Citations
https://www.barudanamerica.com/wp-content/uploads/2018/11/XS-XY_Error_Messages.pdf
type: manual · retrieved: 2026-11-21 · locator: p. 1
A01 No or Low Battery Voltage Error
Independent and unofficial. Verify against the manual for your exact model and serial number before acting. See this code on the owning surface: FaultDesk.